Now more than ever, vSAN deployments are quickly growing in number. There are many vSAN documents available on StorageHub with great content; from design guides to day 2 operations, but a common ask from the field relates to vSAN deployment considerations. While there are many areas we can explore, some of them vary based on hardware selected, needs and requirements, as well as different deployment scenarios such as 2-node or stretched clusters.

However, there are some considerations that can be applied to most deployment scenarios based on availability, sizing, performance, and features. Number of nodes is probably the most common consideration talked about. We have a requirement of a minimum of three nodes for a vSAN cluster two physical nodes, if you use the 2-node option with Witness Applianceand such minimum comes down to quorum, and math.

We need an uneven number of hosts to have a majority, and three is the lowest number in order to meet the default policy. Having an additional node beyond the minimum required, increases your failure domains; allowing you to rebuild data vSAN self-healing in case of a host outage or extended maintenance.

Keep in mind that some vSAN capabilities are dependent on a minimum number of hosts within the cluster, such as Erasure Coding. I know… what about price? Another consideration is to go with single-socket nodes vs.

As far as licensing, vSAN uses per-CPU licensing in most cases, so replacing a dual-socket node with two single-socket nodes maintains the same number of vSAN licenses needed two, in this case.

Single socket nodes are cheaper than dual socket nodes, so it is in your best interest to price both options. You may be pleasantly surprised! Like any other storage solutions, sizing is important. Another important aspect to consider is to properly size the cache layer. John Nicholson wrote a blog about this here. To help you with the vSAN sizing exercises, the vsan sizer tool is a great, and easy way to help you through this. This tool takes into considerations some of the items previously discussed.

This tool is constantly being updated in order to help facilitate faster sizing results, in a more simplified manner. Up until vSAN 6. Starting on vSAN 6. See vSAN 6.In this next post, I will examine some failure scenarios. There are two host failure scenarios highlighted below which can impact a virtual machine running on VSAN:.

The ESXi host on which the virtual machine is running is unaffected, therefore the VM itself continues to run. A reconstruction of the replica storage objects that resided on the failed node is started after a timeout period of 60 minutes this will allow enough time for host reboots, short periods of maintenance, etc.

There is a video of this behaviour here. Again, as before, a reconstruction of the storage objects that used to reside on the failed node is started after a timeout period.

VSAN Part 9 – Host Failure Scenarios & vSphere HA Interop

There is another video of this behaviour here. Resynchronization Behaviour.

How to fix roblox error code 773

VSAN maintains a bitmap of changed blocks in the event of components of an object being unable to synchronization due to a failure of a host, network or disk.

This allows updates to VSAN objects composed of two or more components to be reconciled after a failure. For example, in a distributed RAID-1 mirrored configuration, if a write is sent to nodes A and B for object X, but only A records the write before a cluster-wide power failure, on recovery, A and B will compare their logs for X and A will deliver its copy of the write to B.

These heartbeats play a significant role in determining virtual machine ownership in the event of a vSphere HA cluster partition event.

This means that if partitioning occurs, vSphere HA cannot use datastore heartbeats to determine if another partition can power on the virtual machines before this partition powers it off.

This feature is very advantageous to vSphere HA when deployed on shared storage, as it allows some level of coordination between partitions. This feature is not available to VSAN deployments since there is no shared storage. If a VSAN cluster partitions, there is no way for hosts in one partition to access the local storage of hosts on the other side of the partition; thus no use for vSphere HA heartbeat datastores.

Check out all my VSAN posts here. View all posts by Cormac. There is no requirement for heartbeat datastores. Not at all β€” you can certainly setup your DC in a box.

For instance, if there was a cluster partition, a master would use the heartbeat datastores to determine if hosts in the other partition have failed, or are actually still running. Since there is no way for hosts on either side of a partitioned VSAN cluster to access the storage on the other side of the partition, VSAN hosts cannot make use of heartbeat datastores.

VMware VSAN – Virtual SAN – How to configure

I already hinted at this on twitter, but what to do if total disaster strikes? For whatever reason there will be people who neglect a good backup and they will want to recover their data.

As the new filesystem for VSAN is a proprietary one, is there any chance on recovery using forensics? Or is a customer in this case at the end of the line? This will be the same scenario as having a VM on local storage, and the local disk fails.New in 6. With the ability to directly connect the vSAN data network across hosts, and send witness traffic down an alternate route, there is no requirement for a high speed switch for the data network in this design. This lowers the total cost of infrastructure to deploy 2 Node vSAN.

This can be a significant cost savings when deploying vSAN 2 Node at scale. This is easily done in the vSphere Web Client.

To tag a VMkernel interface for "Witness" traffic, today it has to be done at the command line. To add a new interface with Witness traffic is the type, the command is:. We can configure a new interface for vSAN data traffic using this command rather than using the Web Client. Notice that vmk0, the management VMkernel interface in this example, has Witness traffic assigned. In the example shown, vmk0, on each data node, requires connectivity to the VMkernel port vmk1 on the Witness Appliance.

The vmk2 interface on each data node could be direct connected. If we have dual nics for redundancy, we could possibly assign vMotion traffic down the other 10Gbps nic. Stay tuned. Thank you! This helped me very much. Thank you for the video. It helped show me how to setup the networking. The part that had me stumped for awhile, was how to configure only 1 nic per port group.

VMware VSAN – 3-nodes mode

I finally found the setting editing the distributed port group settings. Then clicking on Teaming and failover I configured 1 uplink active and the other to standby.

Actually 2 Node vSAN has been supported since 6. Hi, Does it require vcenter also to be version above 6 update 3 for a 2 node direct connect setup? Since direct connect is used and the witness traffic is carried over management vmk, what to do with the WitnessPg vmk in witness esxi host? Hi Mr. So as I understand, the witness appliance is required anyway, even in this case of two nodes attached directly by the 10 GigaB NIC.

Is that right?? Thank you in advance for your gently reply. Best regards Dante Carlini. Hi Jase I have configured this but it seems incorrect with messages saying 0 witness detected etc. Or is there a NW rest required of some sort?

Sorry for the late response, just seeing this. Your vCenter should be at least vCenter 6.

Areia branca rn

Fully supported. Apologies for the late replies folks, it would appear there is a routing issue for comment moderation. Thanks for the great article. I am new to vSAN, and having some issues here and there.

Is this correct? Or do I also need to set this adapter to witness type traffic? Could the commands in the article be fixed?With software defined storage, it has opened new opportunities to new skills. The witness object is on a third host.

vsan 3 host configuration

As there are low number of esxi server in the cluster, you might see following limitation in the cluster. When a esxi host goes down, vSAN cannot rebuild Virtual Machine data on another esxi server to safeguard against another failure. Another thing if a Esxi is put onto enter maintenance mode, vSAN cannot reprotect evacuated data. Data is uncovered to a possible catastrophe while the host is in maintenance mode.

In my environment I am running vcenter server 6. Before starting configuration one of the prerequisite is disable vSphere HA high availability. Select the clusteron the configure tab in the right, expand services and select vSphere Availabilityclick Edit.

Make sure you are atleast using 10 Gig network adpater for vSAN network traffic. Press Configure button.

vsan 3 host configuration

It opened the Configure vSAN wizard. Under the vSAN capabilities there are several services and options, select them how you want your vSAN cluster to work. Enabling or disabling deduplication and compressionrequires a rolling reformt of all disks in the VSAN cluster, Depending on the amount of data stored, this might take a long time. To achieve this change, vSAN evacuates data from the disk group, removes the disk group, and recreates it with a new layout format that provisions deduplication and compression.

A fault domain typically mentions to a group of hardware devices that would be impacted by an outage, I am using normal cluster without Fault domain or stretched cluster. Click next to proceed. On the Network validation, check the existing vSAN network settings on all the hosts in the cluster.

Make sure you have created configured one vmkernel adapter portgroup on each esxi host with vSAN option enabled. On the Claim disks, select the disks to contribute to the vSAN datastore, Select which disks should be claimed for chache and which for capacity in the vSAN cluster. The disks below are grouped by model and size or by host.

The recommended selection has been made based on the available devices in your environment. The number of capacity disks must be greater than or equal to the number of cache disks claimed per host.

VMware vSAN Setup

Here you can make your disk appear as flash or HDD as shown in the icon. Next Select cache tier and capacity tier selecting from drop down box.There are a number of pre-requisites that are needed, prior to configuring a vSphere cluster to participate as a VSAN.

The following list shows the minimum requirements to implement a VSAN. Hosts without storage can still participate in the cluster, they will only provide compute resources. The simplest way of doing this is to add each host to vCenter without joining a cluster. Once the hosts are added to vCenter we can begin the configuration. We now need to confirm that the host meets the pre-requisites for the storage.

As described above, we need at least 1 SSD and 1 Hard disk. To do this follow the steps below:. Complete all the steps in this section for every host that will be providing storage resources to the VSAN cluster. After following the steps in the previous section, we are now ready to create our VSAN cluster. Create a cluster following the standard steps, but do not enable any of the vSphere cluster features.

We will enable these in a later step. We can now begin to add hosts to this created cluster. The simplest way to carry out this action is use the Move Hosts into Cluster option by right clicking on the cluster object. Once the hosts have been added to the cluster, we can begin to configure and enable VSAN. We will now add the hosts disks to a disk group and create a Datastore.

As previously mentioned, this would normally be done Automatically, if we had selected that option when configuring VSAN. VMwarevsan.

Thank you for your warm welcome to the team

Name required. Email will not be published required. Notify me of follow-up comments by email. Notify me of new posts by email. This site uses Akismet to reduce spam. Learn how your comment data is processed. By admin on August 26, in Storage. Like this: Like Loading Leave a Reply Click here to cancel reply. Comment Name required Email will not be published required Website Notify me of follow-up comments by email. Sorry, your blog cannot share posts by email.Please help me to fix this isseu.

I need all the VSAN experts here. I not finding any troubleshooting solution for this issue. I created VMkernel network. Don't know why??

Dell g5 5590 fan control

Actually it is 6GB. Do we have any official VMware documentation which talks about the ratio of Memory requirement vs No of disks???

vSAN Stretched Cluster Guide

I have not seen this officially documented, but mainly because all "physical" deployments typically will have more than 32GB of memory.

Error: You don't have JavaScript enabled. This tool uses JavaScript and much of it will not work correctly without it enabled.

Please turn JavaScript back on and reload this page. Please enter a title. You can not post a blank message. Please type your message and try again. I have the same question Show 0 Likes 0. This content has been marked as final. Show 15 replies. Thanks DBN. Do you have multicast on L2 enabled on your physical switch to which the hosts are connected? Yes Duncan i did it It should be at least 5GB.

Minimum requirement is 4 GB.

vsan 3 host configuration

Thanks Duncan and Deepan I will increase memory to 5 GB and check. Here is a post I did on the memory requirements which came into effect for GA.

Go to original post. Retrieving data Correct Answers - 10 points.Design the configuration of hosts and management nodes for best availability and tolerance to consumption growth.

The more failures the cluster is configured to tolerate, the more capacity hosts are required. If the cluster hosts are connected in rack servers, you can organize the hosts into fault domains to improve resilience against issues such as top-of-rack switch failures and loss of server rack power.

In a three-host configuration, you can tolerate only one host failure by setting the number of failures to tolerate to 1. The witness object is on a third host. Because of the small number of hosts in the cluster, the following limitations exist:.

You can use only the Ensure data accessibility data evacuation option. Ensure data accessibility guarantees that the object remains available during data migration, although it might be at risk if another failure occurs.

When the host exists maintenance mode, objects are rebuilt to ensure policy compliance. In any situation where two-host or three-host cluster has an inaccessible host or disk group, vSAN objects are at risk of becoming inaccessible should another failure occur.

Using hosts with different configurations has the following disadvantages in a vSAN cluster:. If the vCenter Server becomes unavailable, vSAN continues to operate normally and virtual machines continue to run. Limitations of a Two-Host or Three-Host Cluster Configuration In a three-host configuration, you can tolerate only one host failure by setting the number of failures to tolerate to 1.

Because of the small number of hosts in the cluster, the following limitations exist: When a host fails, vSAN cannot rebuild data on another host to protect against another failure. If a host must enter maintenance mode, vSAN cannot evacuate data from the host to maintain policy compliance. While the host is in maintenance mode, data is exposed to a potential failure or inaccessibility if an additional failure occurs. Using hosts with different configurations has the following disadvantages in a vSAN cluster: Reduced predictability of storage performance because vSAN does not store the same number of components on each host.

Different maintenance procedures. Reduced performance on hosts in the cluster that have smaller or different types of cache devices.